کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1199760 1493561 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A novel automated hydrophilic interaction liquid chromatography method using diode-array detector/electrospray ionization tandem mass spectrometry for analysis of sodium risedronate and related degradation products in pharmaceuticals
ترجمه فارسی عنوان
روش جدید کروماتوگرافی مایع متقاطع هیدروفیلی اتوماتیک با استفاده از طیف سنجی جرمی دو طرفه یابنده ی دیاگرام / الکترو اسپری یونیزاسیون برای تجزیه و تحلیل ریزدرونیت سدیم و محصولات تخریب آن در داروها
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• HPLC fused core technology to analyze SR and its degradation products.
• Stress test studies on raw material, finished products and placebos.
• No interference of the complex matrices (new pharmaceuticals) was observed.
• The main degradation product (SR N-oxide) was characterized by HPLC-ESI-MS.

A simple, sensitive and fast hydrophilic interaction liquid chromatography (HILIC) method using ultraviolet diode-array detector (UV-DAD)/electrospray ionization tandem mass spectrometry was developed for the automated high performance liquid chromatography (HPLC) determination of sodium risedronate (SR) and its degradation products in new pharmaceuticals. The chromatographic separations were performed on Ascentis Express HILIC 2.7 μm (150 mm × 2.1 mm, i.d.) stainless steel column (fused core). The mobile phase consisted of formate buffer solution (pH 3.4; 0.03 M)/acetonitrile 42:58 and 45:55 (v/v) for granules for oral solution and effervescent tablet analysis, respectively, at a flow-rate of 0.2 mL/min, setting the wavelength at 262 nm. Stability characteristics of SR were evaluated by performing stress test studies. The main degradation product formed under oxidation conditions corresponding to sodium hydrogen (1-hydroxy-2-(1-oxidopyridin-3-yl)-1-phosphonoethyl)phosphonate was characterized by high performance liquid chromatography-electrospray ionization-mass tandem mass spectrometry (HPLC-ESI-MS/MS). The validation parameters such as linearity, sensitivity, accuracy, precision and selectivity were found to be highly satisfactory. Linear responses were observed in standard and in fortified placebo solutions. Intra-day precision (relative standard deviation, RSD) was ≤1.1% for peak area and ≤0.2% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all the examined compounds (from 98.7 to 101.0%) with RSD ranging from 0.6 to 0.7%. The limits of detection (LOD) and quantitation (LOQ) were 1 and 3 ng/mL, respectively. The high stability of standard and sample solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed stability indicating method is suitable for the quality control of SR in new and commercial pharmaceutical formulations.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1365, 24 October 2014, Pages 131–139
نویسندگان
, , , , ,