کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1200922 1493627 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Polyethersulfone solid-phase microextraction followed by liquid chromatography quadrupole time-of-flight mass spectrometry for benzotriazoles determination in water samples
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Polyethersulfone solid-phase microextraction followed by liquid chromatography quadrupole time-of-flight mass spectrometry for benzotriazoles determination in water samples
چکیده انگلیسی


• Microextraction of polar benzotriazoles with a disposable polyethersulfone sorbent.
• Selective determination of benzotriazoles by LC–QTOF-MS.
• Comparison with other microextraction techniques (SBSE and DLLME).
• Assessment of benzotriazole levels in urban sewage and surface water samples.

A microextraction method for the determination of 1H-benzotriazole (BTri), and four polar derivatives (4 and 5-methyl-1H-benzotriazole, 4-TTri and 5-TTri; 5,6-dimethyl-1H-benzotriazole, XTri; and 5-chloro-1H-benzotriazole, 5-ClBTri), in surface and wastewater samples is presented. Analytes were pre-concentrated using a disposable, low cost polyethersulfone (PES) sorbent and further analysed by liquid chromatography quadrupole time-of-flight mass spectrometry (LC–QTOF-MS). Parameters affecting the efficiency of sample preparation (extraction conditions and desorption solvent) and those controlling the performance of LC–MS determination were investigated. Analytes were extracted from 15 mL water samples, containing a 30% (w/v) of sodium chloride (4.5 g) and adjusted at pH 4.5, using a tubular PES sorbent (5 cm length × 0.7 mm o.d., sorbent volume 42 μL). After methanol desorption and solvent exchange, benzotriazoles were determined by LC–MS, with chromatograms extracted using a mass window of 20 ppm, centred in their [M+H]+ ions. The identity of chromatographic peaks was confirmed with accurate ion product scan (MS/MS) spectra. The method provided limits of quantification (LOQs) between 0.005 and 0.100 μg L−1, and relative recoveries from 81% to 124% (except for XTri in sewage samples, ca. 60%) with associated standard deviations between 2% and 9%. When compared with polydimethylsiloxane covered stir-bars (coating volume 24 μL), the PES polymer achieved significant higher responses (5–20-fold) for these polar pollutants. BTri and tolyltriazoles (4-TTri and 5-TTri) were found in urban sewage and river water samples, affected by wastewater discharges, with the maximum concentration (5.9 μg L−1) corresponding to BTri in raw wastewater.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1299, 19 July 2013, Pages 40–47
نویسندگان
, , , ,