کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1203059 1493696 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of phenols with ion chromatography–online electrochemical derivatization based on porous electrode–fluorescence detection
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of phenols with ion chromatography–online electrochemical derivatization based on porous electrode–fluorescence detection
چکیده انگلیسی

The current study describes the determination of phenols using ion chromatography–online electrochemical derivatization–fluorescence detection (IC/ED/FD). Six model phenols including 4-methylphenol (pMP), 2, 4-dimethylphenol (DMP), 4-tert-butylphenol (TBP), 4-hydroxylphenolacetic acid (pHPA), 4-acetamidophenol (pAAP), and phenol (P) were well separated on an anion-exchange column under ion exchange mode using NaOH with small amount of acetonitrile added as eluent. Online electrochemical derivatization performed via a laboratory-made electrolytic cell (EC), consisting of porous titanium electrode and cation-exchange membrane (CEM), allows the oxidation products that are strongly fluorescent to be detected by the fluorescence detector. NaOH eluent used in the present method matches well with the maximal fluorescence intensity obtained at alkaline condition for oxidized phenols, thus the addition of specific buffer solution after oxidation encountered in previous report could be eliminated. This process leads to a simplified procedure. The proposed method was sensitive to the limits of detection in the range of 0.4 μg/L and 3.8 μg/L and the limits of quantification between 1.2 μg/L and 13 μg/L due to the strong electro-oxidation capacity of porous titanium electrode, as well as the implementation of time-programmed potential over EC. The linear ranges were 2.0–1.0 × 104 μg/L for pAAP and DMP, and 10–1.0 × 104 μg/L for P, pMP, pHPA, and TBP, respectively. The relative standard deviations range from 0.9% to 4.8%. The utilization of the method was demonstrated by the analysis of real samples. The average spiked recoveries of target analytes in pool water were 81.0–118%.


► Analysis of phenols by ion chromatography/online post-column electrochemical derivatization/fluorescence detection.
► The method was sensitive due to strong oxidation capacity of porous electrode.
► Time-programmed potential over EC enables every phenol to reach its maximum sensitivity.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1229, 16 March 2012, Pages 288–292
نویسندگان
, , , ,