1203444 | 965113 | 2010 | 5 صفحه PDF | دانلود رایگان |

Biocompatible poly(ethylene glycol methyl ether acrylate-co-polyethylene glycol diacrylate) monoliths were prepared for size exclusion chromatography (SEC) of proteins in the capillary format using Brij 58P in a mixture of hexanes and dodecanol as porogens. The monolithic columns provided size separation of four proteins in 20 mM sodium phosphate buffer (pH 7.0) containing 0.15 M NaCl, and there was a linear relationship between the retention times and the logarithmic values of the molecular weights. Compared to SEC monoliths previously synthesized using a triblock copolymer of polyethylene oxide and polypropylene oxide, an increase in mesoporosity was confirmed by inverse size exclusion chromatography. As a result, improved protein separation in the high molecular weight range and reduced column back-pressure were observed.
Journal: Journal of Chromatography A - Volume 1217, Issue 52, 24 December 2010, Pages 8181–8185