Determination of gamma-hydroxybutyric acid in serum and urine by headspace solid-phase dynamic extraction combined with gas chromatography–positive chemical ionization mass spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of gamma-hydroxybutyric acid in serum and urine by headspace solid-phase dynamic extraction combined with gas chromatography–positive chemical ionization mass spectrometry
چکیده انگلیسی

Gamma-hydroxybutyric acid is an emerging drug of abuse. Beside relaxation and euphoria it causes hypnosis and unconsciousness. Therefore the substance is misused as recreational drug and at drug-facilitated sexual assaults. An automated and effortless method for quantitation of gamma-hydroxybutyric acid in serum and urine was optimized and validated. Five hundred microliters sample volume are used for both matrices. The acid catalyzed conversion of gamma-hydroxybutyric acid to the corresponding gamma-butyrolactone is applied. Furthermore the method is based on headspace solid-phase dynamic extraction coupled with gas chromatography–mass spectrometry. The extraction process is performed by repeated aspiration and ejection of the headspace through a steel cannula which is coated on the inside with a polydimethylsiloxane sorbent. Thus absorption of analyte molecules by the sorbent is achieved. The influence of parameters as sorbent type, incubation temperature, number of extraction strokes, injection port temperature and injection flow speed on extraction recovery was investigated. The validation revealed good accuracy with a bias less than ±5%. Intra- and interday precision determined at 10, 50 and 150 μg/ml for each matrix were in following ranges: 1.96–3.49% (intraday, serum), 2.38–4.31% (intraday, urine), 2.33–5.13% (interday, serum) and 2.53–5.64% (interday, urine). The method provided good linearity between 2 and 200 μg/ml yielding coefficients of determination R2 ≥ 0.9985. Limit of detection were determined at 0.16 μg/ml for serum and 0.17 μg/ml for urine, respectively. This method exhibits a fast, solvent-free and widely automated extraction process. It has been applied to toxicological routine analysis and therapeutic drug monitoring successfully.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1216, Issue 18, 1 May 2009, Pages 4090–4096
نویسندگان
, , ,