کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1209810 965353 2006 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Monitoring erythrocytes in a microchip channel that narrows uniformly: Towards an improved microfluidic-based mimic of the microcirculation
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Monitoring erythrocytes in a microchip channel that narrows uniformly: Towards an improved microfluidic-based mimic of the microcirculation
چکیده انگلیسی

The release of adenosine triphosphate (ATP) from red blood cells (RBCs) flowing through PDMS microchannels has been determined as a function of channel cross-sectional area using a design containing a channel that narrows uniformly. ATP, released from the RBCs in response to the mechanical deformation of their cell membranes, increased as the channel cross-section decreased. One sample of rabbit RBCs released 1.16 ± 0.11, 1.92 ± 0.14 and 2.09 ± 0.10 μM ATP as the median cross-sectional area decreased from 4314 to 3192 to 2052 μm2, respectively. Numerous samples (n = 6) displayed the same trend. Incubating a sample of RBCs with diamide, a substance known to stiffen cell membranes without harming the cell cytosol, provided evidence that no cell lysis occurred in the microchip device. This novel use of lab-on-a-chip technology allows for channel designs that enable an in vitro study of physiological events that occur in the microcirculation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1111, Issue 2, 14 April 2006, Pages 220–227
نویسندگان
, , ,