کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1213606 1494139 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for monitoring drug exposure in hematopoietic stem cell transplant recipients
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for monitoring drug exposure in hematopoietic stem cell transplant recipients
چکیده انگلیسی

A liquid chromatography–tandem mass spectrometry method was developed for the quantification of circulating levels of multiple immunosuppressant drugs including cyclosporine (CsA), tacrolimus, methotrexate (Mtx), prednisone, prednisolone, methylprednisone, total and free mycophenolic acid (MPA), as well as MPA phenolic (MPAG) and acyl (AcMPAG) glucuronide metabolites. Linearity, precision and accuracy were validated within the typical therapeutic range of concentrations for each compound. The assay was linear over 0.125–25 ng/mL for tacrolimus, 1–500 ng/mL for prednisone/methylprednisone, 2–400 ng/mL for Mtx, 2–1000 ng/mL for prednisolone and from 7.5 to 1500 ng/mL for CsA with the lowest limit of quantification (LLOQ) being 0.125, 1.00, 2.00, 2.00 and 7.5 ng/mL, respectively. The calibration curve concentrations for MPA and MPAG ranged from 50 to 50,000 ng/mL (LLOQ: 50 ng/mL) and 10 to 10,000 ng/mL (LLOQ: 10 ng/mL) for AcMPAG. Mean recoveries in blood and plasma were 84% ± 5.7%. The method could measure individual drugs with high sensitivity, accuracy (bias ≤ 14%), and reproducibility (CV ≤ 12.8%). Its clinical application was validated by measuring levels of these drugs in samples obtained from hematopoietic stem cell transplant recipients treated with combined immunosuppressive drug therapy. Our results indicate that this approach is suitable for simultaneous determination of in vivo levels of immunosuppressive drugs commonly used in combined therapies.


► We developed a LC–MS/MS method for the simultaneous monitoring of multiple immunosuppressive drugs in blood.
► The validated method demonstrates sensitivity, accuracy and reproducibility.
► Its clinical application has been validated in samples from transplant recipients.
► The method is convenient for therapeutic drug monitoring and large-scale studies.