کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1221367 1494640 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous determination of puerarin, daidzin, daidzein, paeoniflorin, albiflorin, liquiritin and liquiritigenin in rat plasma and its application to a pharmacokinetic study of Ge-Gen Decoction by a liquid chromatography–electrospray ionization-tandem m
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simultaneous determination of puerarin, daidzin, daidzein, paeoniflorin, albiflorin, liquiritin and liquiritigenin in rat plasma and its application to a pharmacokinetic study of Ge-Gen Decoction by a liquid chromatography–electrospray ionization-tandem m
چکیده انگلیسی


• A LC–MS/MS method was developed for determination of seven compounds in rat plasma.
• The validated method was successfully applied to a pharmacokinetic study of GGD.
• It might provide a basis for clarifying the active compounds of GGD in treating PD.

A liquid chromatography–electrospray ionization-tandem mass spectrometry (LC–ESI-MS/MS) method was developed and validated for simultaneous determination of seven constituents including puerarin, daidzin, daidzein, paeoniflorin, albiflorin, liquiritin and liquiritigenin in rat plasma using schisandrin as the internal standard (IS). The plasma samples were pretreated by a one-step direct protein precipitation with acetonitrile. The chromatographic separation was carried out on a C18 column with a gradient mobile phase consisting of acetonitrile and water (containing 0.1% formic acid and 5 mM ammonium acetate). All analytes and IS were quantitated through electrospray ionization in positive ion multiple reaction monitoring (MRM) mode. The mass transitions were as follows: m/z 417.5 → 297.2 for puerarin, m/z 417.1 → 255.2 for daidzin, m/z 255.2 → 152.4 for daidzein, m/z 498.1 → 179.3 for paeoniflorin, m/z 481.1 → 197.3 for albiflorin, m/z 436.2 → 257.3 for liquiritin, m/z 257.2 → 137.3 for liquiritigenin and m/z 415.0 → 384.2 for IS, respectively. All calibration curves exhibited good linearity (r > 0.9979) over a wide concentration range for all components. The intra-day and inter-day precisions (RSD) at three different levels were both less than 14.3% and the accuracies (RE) ranged from −13.2% to 14.8%. The extraction recoveries of the seven compounds ranged from 72.9% to 117.4%. The validated method was successfully applied to pharmacokinetic study of the seven components in female rat plasma after oral administration of Ge-Gen Decoction aqueous extract.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 95, July 2014, Pages 76–84
نویسندگان
, , , , , , , ,