چکیده انگلیسی


• A novel fully automated lab-on-a-chip biosensor was engineered and fabricated.
• A novel polymer was designed and synthesized for sample clean-up prior to MiSens assays.
• MiSens sensor is capable of detecting aflatoxins in trace amounts.
• Sensor results were successfully compared and confirmed with ELISA and HPLC.
• Food sample analysis was achieved using the novel lab-on-a-chip biosensor.

Polymers were synthesized and utilized for aflatoxin detection coupled with a novel lab-on-a-chip biosensor: MiSens and high performance liquid chromatography (HPLC). Non-imprinted polymers (NIPs) were preferred to be designed and used due to the toxic nature of aflatoxin template and also to avoid difficult clean-up protocols. Towards an innovative miniaturized automated system, a novel biochip has been designed that consists of 6 working electrodes (1 mm diameter) with shared reference and counter electrodes. The aflatoxin detection has been achieved by a competition immunoassay that has been performed using the new biochips and the automated MiSens electrochemical biosensor device. For the assay, aflatoxin antibody has been captured on the Protein A immobilized electrode. Subsequently the sample and the enzyme-aflatoxin conjugate mixture has been injected to the electrode surfaces. The final injection of the enzyme substrate results in an amperometric signal. The sensor assays for aflatoxin B1 (AFB1) in different matrices were also performed using enzyme link immunosorbent assay (ELISA) and HPLC for confirmation. High recovery was successfully achieved in spiked wheat samples using NIP coupled HPLC and NIP coupled MiSens biosensor [2 ppb of aflatoxin was determined as 1.86 ppb (93% recovery), 1.73 ppb (86.5% recovery), 1.96 ppb (98% recovery) and 1.88 ppb (94.0% recovery) for immunoaffinity column (IAC)-HPLC, NIP-HPLC, Supel™ Tox SPE Cartridges (SUP)-HPLC and NIP-MiSens, respectively]. Aflatoxin detection in fig samples were also investigated with MiSens biosensor and the results were compared with HPLC method. The new biosensor allows real-time and on-site detection of AFB1 in foods with a rapid, sensitive, fully automated and miniaturized system and expected to have an immense economic impact for food industry.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 160, 1 November 2016, Pages 381–388
نویسندگان
, , , , , , , , , , , ,