کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
225759 464509 2006 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of electric current density on the bactericidal effectiveness of pulsed electric field treatments
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Influence of electric current density on the bactericidal effectiveness of pulsed electric field treatments
چکیده انگلیسی

A procedure applying equivalent pulsed electric field (PEF) treatments of similar peak electric field intensity, total treatment time, and treatment temperature, while delivering different amounts of electric current, was successfully developed in this study. Listeria innocua suspended in McIllvaine buffer was subjected to five PEF treatments, each with a peak electric field intensity of 28.85 kV/cm applied for 60 μs at 44.3 °C, with peak electric currents of 1.94, 2.20, 2.76, 3.51, and 4.21 kA, respectively. To apply the described treatments, the charge voltage, pulsing frequency, and initial temperature and electrical conductivity of the treated media were adjusted, based on calculations made using pertinent fundamental mathematical models. Neither the amount of electric current flowing through the treated product, nor the amount of delivered electric energy or the electric conductivity of the studied media showed any influence on the bactericidal effectiveness of the applied treatments within the studied range.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Food Engineering - Volume 76, Issue 4, October 2006, Pages 656–663
نویسندگان
, , ,