کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2408469 1103175 2007 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Multicenter comparative study of a new ELISA, PLATELIA™ RABIES II, for the detection and titration of anti-rabies glycoprotein antibodies and comparison with the rapid fluorescent focus inhibition test (RFFIT) on human samples from vaccinated and non-vacc
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی ایمونولوژی
پیش نمایش صفحه اول مقاله
Multicenter comparative study of a new ELISA, PLATELIA™ RABIES II, for the detection and titration of anti-rabies glycoprotein antibodies and comparison with the rapid fluorescent focus inhibition test (RFFIT) on human samples from vaccinated and non-vacc
چکیده انگلیسی

The envelope glycoprotein G of rabies virus induces the production of neutralising antibodies, which are important in protection against rabies. Therefore, titration of anti-envelope glycoprotein antibodies is a good indicator of the degree of immunity in people during anti-rabies treatment or after vaccination. According to the World Health Organization (WHO) guidelines, a booster vaccine dose should be given if the rabies antibody titre falls below 0.5 IU/ml. Titration of anti-rabies antibodies is also useful for plasma centers in the preparation and standardization of human anti-rabies gamma-globulins for therapeutic use and to a lesser extent for the diagnosis of rabies in human sera and cerebrospinal fluid (CSF).This paper presents a new enzyme-linked immunosorbent assay (ELISA), PLATELIA™ RABIES II, developed for rabies envelope glycoprotein antibody detection or titration and its comparison to the current reference method (RFFIT). The data collected during validation of the test in a multicenter study are analysed to give a sound overall knowledge of the capabilities of the PLATELIA™ RABIES II, for instance specificity, linearity, accuracy, precision, detection limit and quantitation limit. To this aim, human serum samples from a total of 1348 vaccinated or non-vaccinated people were tested in parallel using the new ELISA and the RFFIT for the presence of anti-rabies antibodies. Data generated indicate a linear relationship across the range of titration between the two methods. The sensitivity reaches 98.6% and the specificity 99.4%.This study indicates that this new ELISA test is as sensitive and specific as the current standardized reference method. The method is simple, safe, rapid and can be considered as a useful alternative to the neutralisation test.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Vaccine - Volume 25, Issue 12, 8 March 2007, Pages 2244–2251
نویسندگان
, , , , , , ,