Detection of Coronary Artery Stenoses by Low-Dose, Prospectively ECG-Triggered, High-Pitch Spiral Coronary CT Angiography
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Detection of Coronary Artery Stenoses by Low-Dose, Prospectively ECG-Triggered, High-Pitch Spiral Coronary CT Angiography
چکیده انگلیسی

ObjectivesWe sought to evaluate the diagnostic accuracy of a new prospectively electrocardiogram (ECG)-triggered high-pitch scan mode for coronary computed tomography angiography (CTA), which allows an effective dose of less than 1 mSv.BackgroundCoronary CTA provides increasingly reliable image quality, but the associated radiation exposure can be high.MethodsSeventy-five patients with suspected coronary artery disease and in sinus rhythm were screened for participation. After exclusion of 25 patients for body weight >100 kg or failure to lower heart rate to ≤60 beats/min, 50 patients were studied by prospectively ECG-triggered high-pitch spiral computed tomography (CT). Coronary CTA was performed using a dual-source CT system with 2 × 128 × 0.6-mm collimation, 0.28-s rotation time, a pitch of 3.4, 100-kVp tube voltage, and current of 320 mA. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within 1 cardiac cycle. Diagnostic accuracy for detection of coronary artery stenoses ≥50% diameter stenosis was determined by comparison to invasive coronary angiography. Per-patient diagnostic performance was the primary form of analysis.ResultsIn all 50 patients (34 males, 59 ± 12 years of age), imaging was successful. For the detection of 16 patients with at least 1 coronary artery stenosis, CT demonstrated a sensitivity of 100% (95% confidence interval [CI]: 79% to 100%) and specificity of 82% (95% CI: 65% to 93%). The positive predictive value was 72% (95% CI: 49% to 89%) and the negative predictive value was 100% (95% CI: 87% to 100%). Sensitivity was 100% (95% CI: 88% to 100%) and specificity was 94% (95% CI: 89% to 97%) on a per-vessel basis. Per-segment sensitivity was 92% (95% CI: 80% to 97%), and specificity was 98% (95% CI: 96% to 98%). Mean dose-length product for coronary CTA was 54 ± 6 mGy · cm, the effective dose was 0.76 ± 0.08 mSv (0.64 to 0.95 mSv).ConclusionsIn nonobese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides high diagnostic accuracy for the detection of coronary artery stenoses.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Imaging - Volume 4, Issue 4, April 2011, Pages 328–337
نویسندگان
, , , , , , , , , ,