کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2939050 1176970 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A Randomized Cross-Over Study for Evaluation of the Effect of Image Optimization With Contrast on the Diagnostic Accuracy of Dobutamine Echocardiography in Coronary Artery Disease : The OPTIMIZE Trial
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
A Randomized Cross-Over Study for Evaluation of the Effect of Image Optimization With Contrast on the Diagnostic Accuracy of Dobutamine Echocardiography in Coronary Artery Disease : The OPTIMIZE Trial
چکیده انگلیسی

ObjectivesThe purpose of this study was to evaluate whether the addition of a contrast agent to dobutamine stress echocardiography (DSE) improves its diagnostic accuracy for coronary artery disease (CAD) and to determine the effect of image quality on the diagnostic impact of contrast agent use in this setting.BackgroundContrast agents can improve endocardial border definition. To date, however, there are no randomized trials that have evaluated the impact of contrast agent use on the accuracy of DSE.MethodsPatients referred for stress testing with dobutamine echocardiography underwent 2 DSE studies: 1 with and 1 without a contrast agent, at least 4 h apart in a randomized order and within a 24-h period.ResultsA total of 101 patients underwent both DSE studies. Similar hemodynamics were achieved during the 2 stress testing sessions. The use of a contrast agent improved the percentage of segments adequately visualized at baseline (from 72 ± 24% to 95 ± 8%) and more so at peak stress (67 ± 28% to 96 ± 7%); both p < 0.001. Interpretation of wall motion with high confidence also increased with contrast agent use from 36% to 74% (p < 0.001). Segment visualization with the use of a contrast agent improved in all views, but was more pronounced in the apical views. In unenhanced DSE, 36% of studies were normal, 51% had ischemia, and 8% were uninterpretable—all of which became interpretable with the use of a contrast agent. When compared with angiography (n = 92; 55 patients with CAD), accurate detection of ischemia was higher with contrast-enhanced studies versus nonenhanced studies (p = 0.02). As endocardial visualization and confidence of interpretation decreased in unenhanced studies, a greater impact of the use of a contrast agent on DSE accuracy was observed (p < 0.01).ConclusionsDuring dobutamine stress echocardiography, contrast agent administration improves endocardial visualization at rest and more so during stress, leading to a higher confidence of interpretation and greater accuracy in evaluating CAD. The lesser the endocardial border visualization, the higher the impact of contrast echocardiography on accuracy.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Imaging - Volume 1, Issue 2, March 2008, Pages 145–152
نویسندگان
, , , , , , , ,