AimsTo evaluate if oxaliplatin is likely to vaporize under HIPEC conditions and to see if it could be a source of pulmonary contamination for surgeons.MethodsThree oxaliplatin concentrations (230, 460 and 920 mg oxaliplatin/l), 3 heating temperatures (41, 43 and 45 °C) and 3 bubbling durations (30, 60 and 90 min) were tested. Drug vaporization was evaluated by using inductively coupled plasma mass spectrometry (ICP-MS) to analyze platinum concentrations in the trap solutions.ResultsAt all concentrations of oxaliplatin solutions, heating temperatures and bubbling trap periods, the quantities of vaporized platinum were always insignificantly lower than 1 μg/l.ConclusionsThe experimental risk of pulmonary contamination of hospital staff during HIPEC procedure appears to be negligible. However a monitoring study with an analysis of samples of the operating theatre and urine from surgical personnel should be carried out to confirm these conclusions.
Journal: European Journal of Surgical Oncology (EJSO) - Volume 33, Issue 5, June 2007, Pages 623–626