کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4482776 1316869 2012 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Biodegradation of the endogenous residue of activated sludge in a membrane bioreactor with continuous or on-off aeration
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات فرآیندهای سطح زمین
پیش نمایش صفحه اول مقاله
Biodegradation of the endogenous residue of activated sludge in a membrane bioreactor with continuous or on-off aeration
چکیده انگلیسی

The goal of this study was to determine the effect of a long sludge retention time on the biodegradation of the endogenous residue in membrane digestion units receiving a daily feed of sludge and operated under either aerobic or intermittently aerated (22 h off-2 h on) conditions. The mixed liquor for these experiments was generated in a 10.4 day sludge retention time membrane bioreactor fed with a synthetic and completely biodegradable influent with acetate as the sole carbon source. It had uniform characteristics and consisted of only two components, heterotrophic biomass XH and endogenous residue XE. Membrane digestion unit experiments were conducted for 80 days without any sludge wastage except for some sampling. The dynamic behaviour of generation and consumption of filtered organic digestion products was characterized in the membrane digestion unit systems using three pore filter sizes. Results from this investigation indicated that the colloidal matter with size between 0.04 μm and 0.45 μm was shown to contain a recalcitrant fraction possibly composed of polysaccharides bound to proteins which accumulated in the membrane digestion unit under both conditions. Modelling the membrane digestion unit results by considering a first-order decay of the endogenous residue allowed to determine values of the endogenous residue decay rate of 0.0065 and 0.0072 d−1 under fully aerobic and intermittently aerated conditions, respectively. The effect of temperature on the endogenous decay rate was assessed for the intermittently aerated conditions in batch tests using thickened sludge from tests gave an endogenous decay rate constant of 0.0075 d−1 at 20 °C and an Arrhenius temperature correction factor of 1.033.


► The endogenous residue biodegradability was evaluated under full or on-off aeration.
► A slow degradation of the endogenous residue was observed under both conditions.
► Decay rates under full and on-off aeration were 0.0065 and 0.0072 d−1, respectively.
► A temperature constant of 1.033 was determined under intermittent aeration.
► Recalcitrant endogenous filtered products were produced under both conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Water Research - Volume 46, Issue 9, 1 June 2012, Pages 2837–2850
نویسندگان
, , , , , ,