کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4929307 | 1432282 | 2017 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Surface support capabilities of freshly sprayed fibre reinforced concrete and safe re-entry time for underground excavations
ترجمه فارسی عنوان
قابلیت پشتیبانی از سطوح بتن مسلح شده تازه فیبر و زمان ورود مجدد برای حفاری های زیرزمینی
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
پشتیبانی زمین حفاری های زیرزمینی، بتن اسپری، مقاومت برشی، زمان مجدد ورود،
موضوعات مرتبط
مهندسی و علوم پایه
علوم زمین و سیارات
مهندسی ژئوتکنیک و زمین شناسی مهندسی
چکیده انگلیسی
Sprayed fibre reinforced concrete support is an important component of modern ground support schemes used for stabilisation of underground excavations in rock. In particular, the safe re-entry time after fibre reinforced concrete has been sprayed needs to be considered as it influences the productivity associated with development rates. It is proposed here that the shear strength of the sprayed fibre reinforced concrete matrix is a better parameter to consider than the Uniaxial Compressive Strength of the overall sprayed fibre reinforced concrete material including coarse aggregates. Consequently, a number of sprayed fibre reinforced concrete paste mixes were prepared and evaluated for strength gain. It was found generally that the shear strength of sprayed fibre reinforced concrete pastes increase exponentially during the first 4Â h of curing in all sprayed fibre reinforced concrete mixes, except when the pastes included a hydration stabiliser. It was found for sprayed fibre reinforced concrete mixes with accelerator, synthetic fibres and aggregates that an average layer of about 50Â mm thickness develops sufficient shear strength of about 20Â kPa within about one hour to support the layer mass and a tetrahedral block with 1Â m edge lengths. For the same sprayed fibre reinforced concrete layer, it was found that the sprayed fibre reinforced concrete layer and a cubic metre block can be supported within about 3Â h and 50Â min when the sprayed fibre reinforced concrete shear strength is estimated to be approximately 97Â kPa.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Tunnelling and Underground Space Technology - Volume 64, April 2017, Pages 34-42
Journal: Tunnelling and Underground Space Technology - Volume 64, April 2017, Pages 34-42
نویسندگان
Hla Aye Saw, Ernesto Villaescusa, Christopher R. Windsor, Alan G. Thompson,