کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5135395 1493435 2017 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simple and sensitive determination of atrazine and its toxic metabolites in environmental water by carboxyl modified polyacrylonitrile nanofibers mat-based solid-phase extraction coupled with liquid chromatography-diode array detection
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simple and sensitive determination of atrazine and its toxic metabolites in environmental water by carboxyl modified polyacrylonitrile nanofibers mat-based solid-phase extraction coupled with liquid chromatography-diode array detection
چکیده انگلیسی


- Carboxyl modified polyacrylonitrile nanofibers mat based SPE was developed.
- Simple but effective extraction of atrazine and its toxic metabolites was achieved.
- Noticeable less consumption of sample, sorbent and organic solvent was required.
- The reusability and durability of the novel sorbent were confirmed.
- The method was successfully applied in fast preparation of actual water samples.

Carboxyl modified polyacrylonitrile nanofibers mat (COOH-PAN NFsM) was prepared as a novel solid-phase extraction (SPE) adsorbent for the rapid and effective extraction of atrazine (ATZ) and its toxic metabolites deisopropylatrazine (DIA) and deethylatrazine (DEA) from environmental water samples. Without any pre-treatment but only with the simple filter, water samples passed through pre-conditioned COOH-PAN NFsM, which integrated extraction, purification and concentration into one single step, and the eluent was directly analyzed by high performance liquid chromatography-diode array detection (HPLC-DAD). Under the optimized conditions, the target analytes in 10 mL of water sample could be completely extracted by only 4 mg of COOH-PAN NFsM, and easily eluted using 400 μL of methanol, indicating a high efficiency in both adsorption and desorption. Satisfactory linearity was achieved in the range of 0.4-40.0 ng mL−1 for DIA, and 0.3-40.0 ng mL−1 for DEA and ATZ. The limit of detection (LODs) were 0.12, 0.09 and 0.09 ng mL−1 for DIA, DEA and ATZ, respectively. The recoveries ranged from 81.35 to 120.32%, with the intra-day and inter-day relative standard deviations of 4.03-9.81% even after the 6-cycle usage of NFsM. And, using just 10 mL loading sample, the LOD had already satisfied the demand of surface water quality monitoring levels, revealing the good sensitivity of the proposed method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1491, 31 March 2017, Pages 16-26
نویسندگان
, , , , , , ,