کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5135411 1493435 2017 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Optimization and validation of a fast supercritical fluid chromatography method for the quantitative determination of vitamin D3 and its related impurities
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Optimization and validation of a fast supercritical fluid chromatography method for the quantitative determination of vitamin D3 and its related impurities
چکیده انگلیسی


- DoE-DS methodology allowed optimization of a rapid, green and robust method.
- Overall UHPSFC method was fully validated according the Total error approach.
- UHPSFC quantitative performances match USP & EP requirements for Vitamin D3 as an API.
- Correction factors permit quantification of impurities with API as external standard.
- Current UHPSFC method is a reliable alternative to NPLC for routine QC of vitamin D3.

In the uprising context of green analytical chemistry, Supercritical Fluid Chromatography (SFC) is often suggested as an alternative to Normal Phase Liquid Chromatography. Indeed, SFC provides fast, efficient and green separations. In this report, the quantitative performances of SFC were challenged on a real-life case study: the Quality Control (QC) of vitamin D3. A rapid and green SFC method was optimized thanks to the Design of Experiments-Design Space (DoE-DS) methodology. It provided robust and high quality separation of the compounds within a 2 min timeframe, using a gradient of ethanol as co-solvent of the carbon dioxide. The analytical method was fully validated according to the total error approach, demonstrating the compliance of the method to the specifications of U.S. Pharmacopeia (USP: 97.0-103.0%) and European Pharmacopeia (EP: 97.0-102.0%) for an interval of [50-150%] of the target concentration. In order to allow quantification of impurities using vitamin D3 as an external standard in SFC-UV, correction factors were determined and verified during method validation. Thus, accurate quantification of impurities was demonstrated at the specified levels (0.1 and 1.0% of the main compound) for a 70.0-130.0% dosing range. This work demonstrates the validity of an SFC method for the QC of vitamin D3 raw material and its application to real samples. Therefore, it supports the switch to a greener and faster separative technique as an alternative to NPLC in the pharmaceutical industry.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1491, 31 March 2017, Pages 171-181
نویسندگان
, , , , , , , ,