کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5472548 1519922 2017 24 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cavitation instabilities of an inducer in a cryogenic pump
ترجمه فارسی عنوان
ناپایداری کاویتاسیون القا کننده در یک پمپ فریزر
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی هوافضا
چکیده انگلیسی
Inducers assist cryogenic pumps to operate safely under cavitation conditions by increasing the pressure of the impeller inlet, but create cavitation instabilities. The use of cryogenic fluids requires special attention because of safety and handling concerns. To examine the cavitation instabilities of a cryogenic pump, two kinds of working fluids, water and liquid oxygen, were employed. The cavitation instabilities were measured with an accelerometer installed on the pump casing. The flow coefficient and the head slightly decrease with decreases in the cavitation number before the cavitation breakdown. These trends are true of both fluids. Several cavitation instabilities were identified with the accelerometer. At lower flow coefficients, super-synchronous rotating cavitation was found in a similar cavitation number range for both fluids. At higher flow coefficients, the cavitation numbers of the cavitation instabilities in the liquid oxygen test are smaller than those of the water test.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Acta Astronautica - Volume 132, March 2017, Pages 19-24
نویسندگان
, , , ,