کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
598228 1454087 2006 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A novel amperometric hydrogen peroxide biosensor based on immobilization of hemoglobin in linoleic acid monolayer by Langmuir–Blodgett technique
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی شیمی کلوئیدی و سطحی
پیش نمایش صفحه اول مقاله
A novel amperometric hydrogen peroxide biosensor based on immobilization of hemoglobin in linoleic acid monolayer by Langmuir–Blodgett technique
چکیده انگلیسی

In this paper, we reported a novel amperometric hydrogen peroxide (H2O2) biosensor for the first time based on immobilization of hemoglobin (Hb) incorporated in linoleic acid (LA) on gold electrode surface by Langmuir–Blodgett (LB) technique. Atomic force microscopy image of Hb–LA LB film indicated that Hb molecules existed in LA layer with a well-ordered and compact form. The electrode modified with Hb–LA LB film displayed a couple of stable and well-defined redox peaks with a peak-to-peak separation of 80 mV, indicating that the electron transfer between Hb and electrode was accelerated by Hb incorporated in LA monolayer. This modified electrode showed the electrochemical activity to reduction of H2O2 without aid of any electron mediator. Under the optimal conditions, a linear dependence of the catalytic current versus H2O2 concentration was obtained in the range of 2.0–100.0 μM with a detection limit of 1.2 μM.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Colloids and Surfaces A: Physicochemical and Engineering Aspects - Volumes 284–285, 15 August 2006, Pages 125–129