کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6662611 | 463225 | 2014 | 7 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Amperometric immunosensor of Brucella abortus CE-protein antigen shows post-zone phenomena
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
DEARBPTSPELPSPBSALP - آلکالن فسفاتازAlkaline phosphatase - آلکالین فسفاتاز یا فسفاتاز قلیاییenzyme linked immunosorbent assay - آنزیم تست ایمونوسیورسانس مرتبط استScreen printed electrode - الکترود چاپ شده روی صفحهImmunosensor - ایمونوسنسورCAB - تاکسیELISA - تست الیزاdiethanolamine - دی اتانولینRab - ربphosphate buffer saline - فسفات بافر شورlipopolysaccharide - لیپوپلی ساکاریدpolymerase chain reaction - واکنش زنجیره ای پلیمرازPCR - واکنش زنجیرهٔ پلیمرازCyclic voltammetry - ولتامتری چرخهای
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی شیمی
مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
Brucella abortus is an intracellular pathogen of zoonotic nature and causes brucellosis in humans, means it can be transferred from cattle to a human and remains pathogenic. In this study, attempts were made for detection of B. abortus cell envelop protein (CE-protein) antigen by using amperometric immunosensors. Screen printed electrodes were characterized electrochemically with 1-naphthol and used in sandwich enzyme linked immunosorbent assay system to detect CE protein antigen. Linear range was found in the range of 1.56 μg/mL to100 μg/mL with a regression equation of I (nA) = 43.12 + 1.235 (antigen (μg/mL)) (R2 = 0.991). Relative standard deviation was found 5.5%. At high concentrations post-zone like phenomenon was observed. At very low concentrations the response was higher compared to that of at higher concentrations. However, no false results were observed. The detection limit was found to be 0.1 μg/mL. By conventional plate ELISA it is possible to detect 50 μg/mL only. Experiments were conducted using suspected human patient serum samples and results were compared with ELISA and RBPT test. The immunosensor was found to be highly sensitive compared to ELISA and RBPT. In order to confirm that whether these results obtained from electrochemical technique (amperometric technique) was true positive or false positive, we further diluted the patient serum samples and then tested. We found that even after dilution of patient serum samples results obtained were same as before dilution of patient serum samples. Hence, it is concluded that electrochemical technique does not give false result. Thus electrochemical immunosensors can be used for diagnosis of brucellosis in patient serum sample. Shelf life of immunosensor was found 18 days.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electroanalytical Chemistry - Volumes 717â718, 15 March 2014, Pages 83-89
Journal: Journal of Electroanalytical Chemistry - Volumes 717â718, 15 March 2014, Pages 83-89
نویسندگان
Ajay Kumar Gupta, Vepa Kameswara Rao, D.T. Selvam, Ashu Kumar, Rajeev Jain,