کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7048735 1457135 2016 35 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Calculation of Boil-Off Rate of Liquefied Natural Gas in Mark III tanks of ship carriers by numerical analysis
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Calculation of Boil-Off Rate of Liquefied Natural Gas in Mark III tanks of ship carriers by numerical analysis
چکیده انگلیسی
The heat flow from environment to LNG stored in Mark III of ship carriers is calculated in this paper by numerical simulations. Four different approaches are defined and evaluated: Approach 1 starts from simple 2D numerical computations of heat fluxes over representative sections of the insulation barriers in 10 specific temperature configurations defined by published data. Approach 2 evolves toward full 3D simulations of insulations layers under the same temperature configurations. A Reduced Order Model is next developed by calculating equivalent thermal conductivity for insulation barriers. This equivalent thermal conductivity is applied in the fluid flow and heat transfer simulation from the environment to the LNG in 2D and 3D models by Approaches 3 and 4, respectively. For a full ship with a capacity of 165,000 m3 with 270 mm thick insulation barriers, the obtained BOR and the overall heat transfer coefficient vary from 0.895% and 0.0656 W/m2⋅°C for Approach 2 to 0.0945% and 0.0693 W/m2⋅°C for Approach 3. For Approach 4, the BOR and overall heat transfer coefficient are 0.0919% and 0.0674 W/m2⋅°C. When the thickness of the insulation barrier is increased to 400 mm, these initial values are reduced to 0.0631% and 0.0453 W/m2⋅°C.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 93, 25 January 2016, Pages 279-296
نویسندگان
, , , ,