کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7626199 | 1494577 | 2018 | 30 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Liquid chromatography-tandem mass spectrometric assay for therapeutic drug monitoring of the EGFR inhibitors afatinib, erlotinib and osimertinib, the ALK inhibitor crizotinib and the VEGFR inhibitor nintedanib in human plasma from non-small cell lung canc
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
EGFRIQCNintedanibAfatinibLLOQDMSO - DMSOLC–MS/MS - LC-MS / MSALK - آلکErlotinib - ارلوتینیبinternal standard - استاندارد داخلیCalibration standard - استاندارد کالیبراسیونlower limit of quantification - حد پایین کمیت سنجیDimethylsulfoxide - دیمتیل سولفواکسیدNSCLC - سرطان ریوی غیر سلول کوچکNon-small cell lung cancer - سرطان غیر سلول کوچک ریهCoefficient of Variation - ضریب تغییرAnaplastic lymphoma kinase - لنفوم کیناز Anaplasticliquid chromatography coupled with tandem mass spectrometry - کروماتوگرافی مایع همراه با طیف سنجی جرمی دو طرفهCrizotinib - کریزوتینیبinternal quality control - کنترل کیفیت داخلیEpidermal growth factor receptor - گیرنده فاکتور رشد اپیدرمال
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
A new method for the quantitative analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) of five tyrosine kinase inhibitors (afatinib, crizotinib, osimertinib, erlotinib and nintedanib) used in the treatment of non-small cell lung cancer (NSCLC) was developed and validated in human plasma. Separation was performed on an Accucore® C18 (2.1â¯Ãâ¯50â¯mm; 2.6â¯Î¼m) column using a gradient elution of water acidified with 0.1% (v/v) formic acid (A) and acetonitrile containing 0.1% (v/v) formic acid (B) at a flow rate of 500â¯Î¼L/min. The analytes were detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer after positive ionization with heated electrospray interface. After addition of three isotopically labeled internal standards, plasma pretreatment consisted in a simple protein precipitation. This method presented satisfactory results in terms of sensitivity, specificity, precision (intra- and inter-assay coefficient of variation from 2.6% to 10.6%), accuracy (from 96.1% to 108.5%), recovery and matrix effects. The lower limit of quantification and the linearity of these five tyrosine kinases inhibitors are suitable with the expected concentrations in clinical practice. This new bioanalytical method can be used in daily clinical practice for therapeutic drug monitoring of these tyrosine kinase inhibitors in NSCLC patients.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 158, 5 September 2018, Pages 174-183
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 158, 5 September 2018, Pages 174-183
نویسندگان
Rafael Reis, Laurence Labat, Marie Allard, Pascaline Boudou-Rouquette, Jeanne Chapron, Audrey Bellesoeur, Audrey Thomas-Schoemann, Jennifer Arrondeau, Frédérique Giraud, Jérôme Alexandre, Michel Vidal, François Goldwasser, Benoît Blanchet,