کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
867233 909779 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Label-free impedimetric immunosensor for ultrasensitive detection of cancer marker Murine double minute 2 in brain tissue
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Label-free impedimetric immunosensor for ultrasensitive detection of cancer marker Murine double minute 2 in brain tissue
چکیده انگلیسی

The detection of cancer biomarkers is as important tool for the diagnosis and prognosis of cancer such as brain cancer. Murine double minute 2 (MDM2) has been widely studied as prognostic marker for brain tumor. Here we describe development of a new sensitive label free impedimetric immunosensor for the detection of MDM2 based on cysteamine self assembled monolayers on a clean polycrystalline Au electrode surface. The amine-modified electrodes were further functionalized with antibody using homobifunctional 1,4-phenylene diisothiocyanate (PDITC) linker. The assembly processes of the immunosensor had been monitored with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques using Fe(CN)63−/4− solution as redox probe. The impedance changes upon binding of MDM2 protein to the sensor surface was utilized for the detection of MDM2. The increase in relative electron-transfer resistance (ΔR/R0%) values was linearly proportional to the concentration of tumor marker MDM2 in the wide dynamic range of 1 pg/ml-1 μg/ml. The limit of detection was 0.29 pg/ml in phosphate buffer saline (PBS) and 1.3 pg/ml in mouse brain tissue homogenate, respectively. The immunosensor showed a good performance in comparison with ELISA for the analysis of the MDM2 in the cancerous mouse brain tissue homogenates. Moreover, the immunosensor had a good selectivity against epidermal growth factor receptor (EGFR) protein, long-storage stability and reproducibility. It might be become a promising assay for clinical diagnosis and early detection of tumors.


► Impedemetric biosensor developed for the detection of MDM2 brain cancer biomarker.
► Dynamic range of 1 pg/ml to 1 μg/ml in PBS and 1 pg/ml to 100 ng/ml in mouse brain tissue homogenate.
► Detection limit was 0.29 pg/ml, 1.3 pg/ml in PBS and mouse brain tissue homogenate, respectively.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 39, Issue 1, 15 January 2013, Pages 220–225
نویسندگان
, , , , ,