کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
9749326 | 1493807 | 2005 | 13 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Fully automated micro- and nanoscale one- or two-dimensional high-performance liquid chromatography system for liquid chromatography-mass spectrometry compatible with non-volatile salts for ion exchange chromatography
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
R.S.D.ESIPAGEMALDI-TOFIEXMS/MS - MS / MSS/N - S / Npolyacrylamide gel electrophoresis - الکتروفورز ژل پلی آکریل آمیدrelative standard deviation - انحراف استاندارد نسبیIon exchange - تبادل یونیtwo-dimensional - دو بعدیSignal-to-noise - سیگنال به نویزMass spectrometry - طیف سنجی جرمیMass spectrometry (MS) - طیف سنجی جرمی (MS)Tandem mass spectrometry - طیف سنجی جرمی پشت سر هم یا متوالیreversed phase - فاز معکوسMatrix-Assisted Laser Desorption/Ionization Time-of-Flight - مدت زمان پرواز یونیزاسیون لیزر ماتریکس کمک می کندProteomics - پروتئومیکسhigh performance liquid chromatography - کروماتوگرافی مایع با کارایی بالاHPLC - کروماتوگرافی مایعی کاراelectrospray ionization - یونیزاسیون الکترو اسپریElectrospray ionization (ESI) - یونیزاسیون الکترو اسپری (ESI)one-dimensional - یک بعدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
A one- or two-dimensional high performance liquid chromatography system for electrospray ionization mass spectrometers has been developed that is optimized for ion exchange and reversed phase separations. A unique and simple valve configuration permits the use of a variety of non-volatile salts; ammonium sulfate was used in an example of strong cation exchange separations. The system was designed and evaluated for both micro- and nanoflow chromatography. The peptide detection limit was â¼100Â fmol for micro- and 20Â fmol for nanoflow, demonstrating the concentration and mass sensitivity improvements expected with nanoelectrospray ionization. The 1D/2D-HPLC MS system is fully automated for routine peptide analyses, compatible with direct injection of proteolytic digests, and exhibits chromatographic reproducibility and sensitivity. Software permits operator selection of either a 1D or 2D configuration with corresponding system parameters as required for individual samples. The hardware elements and resulting performance are described in this paper.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1063, Issues 1â2, 21 January 2005, Pages 57-69
Journal: Journal of Chromatography A - Volume 1063, Issues 1â2, 21 January 2005, Pages 57-69
نویسندگان
Junichi Masuda, Dawn M. Maynard, Masayuki Nishimura, Teruhisa Ueda, Jeffrey A. Kowalak, Sanford P. Markey,