کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10553977 967946 2005 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Differential pulse voltammetric determination of the dopaminergic agonist bromocriptine at glassy carbon electrode
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Differential pulse voltammetric determination of the dopaminergic agonist bromocriptine at glassy carbon electrode
چکیده انگلیسی
The electrochemical oxidation of bromocriptine at glassy carbon electrode has been carried out in Britton-Robinson (B-R) buffer solutions in the pH range 2.0-11.0 employing cyclic, linear sweep and differential pulse voltammetry (DPV). Bromocriptine showed one well-defined oxidation peak accompanied by a smaller one. The oxidation process was found irreversible. For analytical purposes, the well-resolved diffusion controlled voltammetric peak at pH 5 was critically investigated. The linear relationship between peak current height and bromocriptine concentration allowed the differential pulse voltammetric determination of the drug over a wide concentration range, from 0.04 to 5.00 μg ml−1 with a detection limit of 0.01 μg ml−1. A relative standard deviation of 1.44% at 0.1 μg ml−1 level was obtained. The proposed DPV method was successfully applied for the individual tablet assay to verify the uniformity content of bromocriptine in commercial tablets.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 37, Issue 1, 7 February 2005, Pages 195-198
نویسندگان
, , ,