کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1200088 1493573 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Precision evaluation of chiral capillary electrophoretic methods in the context of inter-instrumental transfer: Constant current versus constant voltage application
ترجمه فارسی عنوان
ارزیابی دقیق روش الکتروفورز مویرگی کریل در زمینه انتقال بین ابزار: جریان فعلی در مقایسه با برنامه ولتاژ ثابت
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Precision evaluation of a capillary electrophoretic method.
• Reduction of Joule heating and resulting temperature fluctuations.
• Investigation of the effect of an applied constant current on the precision.
• Optimizing analytical method transfer conditions for CE.
• Comparison of constant voltage and constant current separations.

Capillary electrophoresis (CE) is an electrophoretic separation technique that was rapidly increasing in popularity some years ago and that led to high expectations. Because of their different separation mechanisms, CE and HPLC are alternative and complementary separation techniques. Chiral molecules can be directly separated with CE by simply adding a chiral selector to the running buffer solution, leading to flexible and cheap methods. Major drawbacks of capillary electrophoretic separation methods are, however, the lower precision compared to HLPC methods and a more problematic analytical method transfer. Both above stated disadvantages limit the generalized use of CE methods in the pharmaceutical industry. Multiple solutions have been suggested to improve the precision of CE methods. In this work the application of a constant current during the electrophoretic separation instead of the more commonly used application of a constant voltage was studied on two CE instruments with different cooling mechanisms. This was done in the context of optimizing method transfer conditions. A constant current may reduce the generation of heat in the capillary and the consequentially radial and axial temperature fluctuations that both negatively influence the precision of the peak areas, migration times and resolutions of a CE method. The repeatability and time-different intermediate precision of both electrophoretic separation modes were compared on two different CE instruments after a successful analytical method transfer. The chiral separations of three beta-blockers, propranolol, sotalol and betaxolol, were used as test cases. A constant current led to a general improvement of the repeatability and time-different intermediate precision of the relative Area Under the Curve of all three beta-blockers, while that of the migration times remained rather constant. It also led to more similar electropherograms than the application of a constant voltage.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1353, 1 August 2014, Pages 140–147
نویسندگان
, , , , ,