کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1667277 1008848 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Investigation of shrinkage and cracking of ophthalmic lens coating by a cycle test of UV radiation and high humidity
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد فناوری نانو (نانو تکنولوژی)
پیش نمایش صفحه اول مقاله
Investigation of shrinkage and cracking of ophthalmic lens coating by a cycle test of UV radiation and high humidity
چکیده انگلیسی
This paper presents some ophthalmic lens coating failures such as shrinkage, cracking, and cracking with delamination caused by UV radiation, elevated temperature, and moisture. These phenomena are caused by: 1) interactions at the interface between the plastic substrate and the hard coating (HC), and 2) plastic deformation with stress and relaxation of the HC/substrate interface. This phenomenon leads to an understanding of the mechanical properties of ophthalmic lenses through a QUV test which is found to be a useful method in developing better ophthalmic lens systems. The coating failures were investigated by means of different analysis techniques including optical microscope, scanning electron microscope, atomic force microscope, thermo mechanical analysis, and dynamic secondary ion mass spectrometry.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Thin Solid Films - Volume 520, Issue 12, 2 April 2012, Pages 4169-4173
نویسندگان
, , , , , , ,