کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
27194 | 44008 | 2012 | 6 صفحه PDF | دانلود رایگان |

A novel, sensitive and high selective flow-injection chemiluminescence (FI-CL) method for the determination of phenol is reported, based upon its decreasing effect on the CL reaction of luminol with hydrogen peroxide catalyzed by manganese (III) deuteroporphyrin [MnDP, Scheme 1, 3] in alkaline solution. Under the selected optimized experimental conditions, the relative CL intensity was linear with phenol in the range of 4.0 × 10−9 to 4.0 × 10−7 g mL−1. The detection limit (3σ) was 6.3 × 10−10 g mL−1 and the relative standard deviation for 1.0 × 10−7 g mL−1 phenol (n = 11) was 2.99%. The regression equation was I = 120.79 + 1.14 × 1010c (R = 0.9936). This method has been applied to the determination of phenol in water with satisfactory results.
► In this study we examine a novel, sensitive and high selective flow-injection chemiluminescence (FI-CL) method for the determination of phenol based upon its decreasing effect on the CL reaction of luminol with hydrogen peroxide catalyzed by manganese deuteroporphyrin in alkaline solution.
► The experimental conditions were optimized.
► Under the selected optimized experimental conditions, the relative CL intensity was linear with phenol in the range of 4.0×10-9 to 4.0×10-7 g mL-1 with the detection limit (3σ) 6.3×10-10 g mL-1.
Journal: Journal of Photochemistry and Photobiology A: Chemistry - Volume 227, Issue 1, 1 January 2012, Pages 32–37