چکیده انگلیسی
The results fit with the concept that a more physiologic electrolyte composition and a higher viscosity of a test solution will, after start of injection of that solution into LCA, delay changes in the electrolyte composition in myocardial interstitial fluid and also delay start of VF. If a plasma isotonic contrast medium (CM) with lower viscosity than that of iodixanol at 320 mgI/mL were created, we conclude that such a CM should have electrolyte composition closer to that of Ringer than present composition (19 mM NaCl and 0.3 mM CaC12) to counteract the effects of faster diffusion of nonphysiologic electrolyte composition from the low-viscosity CM to myocardial interstitial fluid.