کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4482396 1316857 2012 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Occurrence and fate of quinolone and fluoroquinolone antibiotics in a municipal sewage treatment plant
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات فرآیندهای سطح زمین
پیش نمایش صفحه اول مقاله
Occurrence and fate of quinolone and fluoroquinolone antibiotics in a municipal sewage treatment plant
چکیده انگلیسی

This study developed a method for analysis of nineteen quinolone and fluoroquinolone antibiotics (FQs) in sludge samples, and investigated the occurrence and fate of the FQs in a municipal sewage treatment plant (STP) with anaerobic, anoxic, and aerobic treatment processes. Eleven compounds, including pipemidic acid, fleroxacin, ofloxacin, norfloxacin, ciprofloxacin, enrofloxacin, lomefloxacin, sparfloxacin, gatifloxacin, moxifloxacin, and sarafloxacin (only in sludge), were detected in the STP. The predominance of ofloxacin and norfloxacin, followed by lomefloxacin, ciprofloxacin, gatifloxacin, and moxifloxacin, were found in wastewater, suspended solids, and sludge. The total concentrations of FQs were 2573 ± 241 ng/L, 1013 ± 218 ng/L, and 18.4 ± 0.9 mg/kg in raw sewage, secondary effluent, and sludge, respectively. Extremely low mass change percentages were observed for FQs in anaerobic, anoxic, and aerobic treatment units, suggesting biodegradation to be of minor importance in the removal of FQs in STPs. 50–87% of the initial FQs loadings (except for pipemidic acid (36%)) were ultimately found in the dewatered sludge. Mean removal efficiencies of FQs in the STP were 56–75%, except for new generation drugs such as moxifloxacin (40 ± 5%) and gatifloxacin (43 ± 13%). A significant positive correlation was found between removal efficiencies and Kd of FQs. The major factor in the removal of FQs in the STP was sorption to sludge, which was not governed by hydrophobic interactions. The long-term cycling and persistence of FQs in the STP has made activated sludge as a huge reservoir of FQ antibiotics.

Figure optionsDownload high-quality image (128 K)Download as PowerPoint slideHighlights
► Simultaneous analytical method was developed for nineteen FQs in sludge.
► 50–87% of the initial FQs loadings were ultimately found in the dewatered sludge.
► Significant positive correlation was found between removal efficiencies and Kd.
► Sorption to sludge was the major factor for FQs removal.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Water Research - Volume 46, Issue 2, 1 February 2012, Pages 387–394
نویسندگان
, , , ,