کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4484382 1316918 2009 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Changes in characteristics of soluble microbial products in membrane bioreactors associated with different solid retention times: Relation to membrane fouling
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات فرآیندهای سطح زمین
پیش نمایش صفحه اول مقاله
Changes in characteristics of soluble microbial products in membrane bioreactors associated with different solid retention times: Relation to membrane fouling
چکیده انگلیسی

A membrane bioreactor (MBR) is a promising wastewater treatment technology, but there is a need for efficient control of membrane fouling, which increases operational and maintenance costs. Soluble microbial products (SMP) have been reported to act as major foulants in the operation of MBRs used for wastewater treatment. In this study, SMP in MBRs operated with different sludge retention times (SRTs) were investigated by means of various analytical techniques and their relations to the evolution of membrane fouling were considered. Bench-scale filtration experiments were carried out in a laboratory with synthetic wastewater to eliminate fluctuations that would occur with the use of real wastewater and that would lead to fluctuations in compositions of SMP. Three identical submerged MBRs were operated for about 50 days under the same conditions except for SRT (17, 51 and 102 days). Accumulation of SMP in the MBRs estimated by conventional analytical methods (i.e., the phenol–sulfuric acid method and the Lowry method) was significant in the cases of short SRTs. However, the degrees of membrane fouling in the MBRs were not directly related to the concentrations of SMP in the reactors estimated by the conventional analytical methods. Non-conventional analytical methods such as excitation-emission matrix (EEM) fluorescence spectroscopy revealed that characteristics of SMP in the three reactors considerably differed depending on SRT. Foulants were extracted from the fouled membranes at the end of the operation and were compared with SMP in each MBR. It was clearly shown that characteristics of the foulants were different depending on SRT, and similarities between SMP and the extracted foulants were recognized in each MBR on the basis of results of EEM measurements. However, such similarities were not found on the basis of results obtained by using the conventional methods for analysis of SMP. The results of this study suggest that the use of conventional methods for analysis of SMP is not appropriate for investigation of membrane fouling in MBRs.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Water Research - Volume 43, Issue 4, March 2009, Pages 1033–1039
نویسندگان
, , ,