کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4713038 | 1638334 | 2014 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Solute fluxes and geothermal potential of Tacaná volcano-hydrothermal system, Mexico-Guatemala
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
علوم زمین و سیارات
ژئوشیمی و پترولوژی
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Solute fluxes and geothermal potential of Tacaná volcano-hydrothermal system, Mexico-Guatemala Solute fluxes and geothermal potential of Tacaná volcano-hydrothermal system, Mexico-Guatemala](/preview/png/4713038.png)
چکیده انگلیسی
Solute and heat fluxes from thermal springs of Tacaná volcano are estimated by the chloride-inventory method. The thermal springs, located at the northwestern slopes of the volcanic edifice, at altitudes from 1500 to 2000 m above sea level, discharge water enriched in HCO3 and SO4 (up to 1 g kgâ 1 of each one) with temperatures in the 25-63 °C range. There are two distinct groups of springs with a different “chloride-temperature” correlation but with the same 87Sr/86Sr ratio (0.7046 ± 0.0001) indicating the same wall rock composition for different aquifers. Each thermal spring feeds a thermal stream that flows into the main drainage of the area, RÃo Coatán. The total observed chloride discharge from the thermal springs is estimated as 14.8 g sâ 1 and the total measured heat output of ~ 9.5 MW. Considering a deep fluid temperature of 250 °C (calculated using Na-K geothermometer), the corresponding advective heat transport from the deep reservoirs that feed these springs may be estimated as 26 MWt. However, the total chloride output measured in the main drainage (Coatán river) is 4 times higher (~ 59 g sâ 1) than the measured Cl output of thermal springs. This means that other, undiscovered, thermal springs exist in the area and that the natural heat output through thermal springs at Tacaná is significantly higher and depends on the Cl content and temperatures of the unknown thermal water discharges. If chloride concentration in these unknown springs does not exceed 540 mg Lâ 1 (the highest analyzed Cl in Tacaná springs) and the discharge temperature is 50 °C, then the natural heat output can be estimated at least as 22 MWt and the corresponding advective heat transport as ~ 100 MWt.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Volcanology and Geothermal Research - Volume 288, 1 November 2014, Pages 123-131
Journal: Journal of Volcanology and Geothermal Research - Volume 288, 1 November 2014, Pages 123-131
نویسندگان
Nathalie Collard, Yuri Taran, Loïc Peiffer, Robin Campion, Mariana P. Jácome Paz,