کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5135180 1493427 2017 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
High performance separation of quaternary amines using microchip non-aqueous electrophoresis coupled with contactless conductivity detection
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
High performance separation of quaternary amines using microchip non-aqueous electrophoresis coupled with contactless conductivity detection
چکیده انگلیسی


- A methodology based on microchip non-aqueous electrophoresis was explored to separate quaternary amines.
- The developed approach offered capacity of providing separations of up to ten compounds within 180 s.
- The proposed method provided separations with high separation efficiency and baseline resolution.
- Quaternary amines were successfully determined in corrosion inhibitor samples usually used for coating oil pipelines.

This study describes the development of an analytical methodology for the separation of quaternary amines using non-aqueous microchip electrophoresis (NAME) coupled with capacitively coupled contactless conductivity detection (C4D). All experiments were performed using a commercial microchip electrophoresis system consisting of a C4D detector, a high-voltage sequencer and a microfluidic platform to assemble a glass microchip with integrated sensing electrodes. The detection parameters were optimized and the best response was reached applying a 700-kHz sinusoidal wave with 14 Vpp excitation voltage. The running electrolyte composition was optimized aiming to achieve the best analytical performance. The mixture containing methanol and acetonitrile at the proportion of 90:10 (v:v) as well as sodium deoxycholate provided separations of ten quaternary amines with high efficiency and baseline resolution. The separation efficiencies ranged from 8.7 × 104 to 3.0 × 105 plates/m. The proposed methodology provided linear response in the concentration range between 50 and 1000 μmol/L and limits of detection between 2 and 27 μmol/L. The analytical feasibility of the proposed methodology was tested in the determination of quaternary amines in corrosion inhibitor samples often used for coating oil pipelines. Five quaternary amines (dodecyltrimethylammonium chloride, tetradecyltrimetylammonium bromide, cetyltrimethylammonium bromide, tetraoctylammonium bromide and tetradodecylammonium bromide) were successfully detected at concentration levels from 0.07 to 6.45 mol/L. The accuracy of the developed methodology was investigated and the achieved recovery values varied from 85 to 122%. Based on the reported data, NAME-C4D devices exhibited great potential to provide high performance separations of hydrophobic compounds. The developed methodology can be useful for the analysis of species that usually present strong adsorption on the channel inner walls.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1499, 26 May 2017, Pages 190-195
نویسندگان
, , , ,