کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6390742 1628409 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Water reconditioning by high power ultrasound combined with residual chemical sanitizers to inactivate foodborne pathogens associated with fresh-cut products
ترجمه فارسی عنوان
تصفیه آب توسط سونوگرافی با قدرت بالا همراه با مواد ضدعفونی کننده شیمیایی باقی مانده برای غیرفعال کردن پاتوژن های غذا همراه با محصولات تازه
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک دانش تغذیه
چکیده انگلیسی


- HPU and a residual PAA concentration were effective for water reconditioning.
- HPU combined with PAA totally inactivated Escherichia coli O157:H7 and Salmonella.
- Lower efficacy was observed for the inactivation of Listeria monocytogenes.
- OA/PC modified adversely the physico-chemical characteristics of recycled water.

The suitability of high power ultrasound (HPU, 20 kHz, 0.28 kW/l) combined with residual chemical sanitizers for water reconditioning was studied. A synergetic disinfection effect was observed when HPU was combined with peroxyacetic acid (PAA) or a commercial mix of organic acids and phenolic compounds (OA/PC). In recycled water (RW) with a chemical oxygen demand (COD) of 500 mg O2/l, PAA inactivated 2 log units of Escherichia coli O157:H7 at concentrations of 3.2, 6.4, 16 mg/l after 7 min, 2 min, 29 s, respectively. The OA/PC or HPU treatments alone needed 26 min treatments to achieve the same reduction. The addition of TiO2 (5 g/l) to HPU (sonocatalysis) did not improve E. coli O157:H7 inactivation. However, when HPU was combined with a residual concentration of PAA (3.2 mg/l), the total inactivation of E. coli O157:H7 and Salmonella (6 log unit reductions) occurred after 11 min, but for Listeria monocytogenes only 1.7 log reductions were detected after 20 min. When HPU was combined with OA/PC, a synergistic effect for the inactivation of E. coli O157:H7 was also observed, but this sanitizer significantly modified the physical-chemical quality characteristics of the RW. These results show that the residual PAA concentration that can be found in the wash water combined with HPU could result in an environmentally friendlier and toxicologically safer strategy for water reconditioning of the fresh-cut industry. The use of the sanitizer alone requires higher concentrations and/or longer contacts times. Even though the residual PAA in combination with HPU was adequate for water reconditioning, it is not appropriate for the process wash water because this wash water must be instantaneously disinfected.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Food Control - Volume 53, July 2015, Pages 29-34
نویسندگان
, , , , ,