کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
82740 158412 2009 16 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Improved trace gas flux estimation through IRGA sampling optimization
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات علم هواشناسی
پیش نمایش صفحه اول مقاله
Improved trace gas flux estimation through IRGA sampling optimization
چکیده انگلیسی

We examine the theoretical and practical aspects of improving the sampling methods of spectroscopic trace gas sensors of Eddy covariance flux measurement systems. Theory is developed based on non-ideal ventilation devices and existing equations for tube flow and attenuation of non-reactive trace gases and temperature. Model results indicate an optimum design exists which can be expressed in relation to intake tube diameter and which depends upon the ventilation device employed. Field experiment results (employing modified open path IRGAs) show that the use of short intake tubes can reduce flux losses by trace gas signal attenuation while minimizing the adjustments required for density fluctuations, with additional benefits of increased data capture under adverse environmental conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Agricultural and Forest Meteorology - Volume 149, Issues 3–4, 11 March 2009, Pages 623–638
نویسندگان
, , , , ,