کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2580573 1130138 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Modified immunoslotblot assay to detect hemi and sulfur mustard DNA adducts
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست بهداشت، سم شناسی و جهش زایی
پیش نمایش صفحه اول مقاله
Modified immunoslotblot assay to detect hemi and sulfur mustard DNA adducts
چکیده انگلیسی

Sulfur mustard (SM) is an old chemical warfare agent causing blisters (vesicant). Skin toxicity is thought to be partly caused by SM induced DNA damage. SM and the hemi mustard 2-chloroethyl ethyl sulfide (CEES) are bi- and monofunctional DNA alkylating agents, respectively. Both chemicals react especially with N7 guanine. The most abundant adducts are 7-hydroxyethylthioethylguanine for SM (61%) and 7-ethyl thioethylguanine for CEES. Thus, DNA alkylation should serve as a biomarker of SM exposure. A specific monoclonal antibody (2F8) was previously developed to detect SM and CEES adducts at N7 position by means of immunoslotblot (ISB) technique (van der Schans et al. (2004) [16]). Nitrogen mustards (HN-1, HN-2, HN-3) are alkylating agents with structural similarities, which can form DNA adducts with N7 guanine. The aim of the presented work was to modify the van der Schans protocol for use in a field laboratory and to test the cross reactivity of the 2F8 antibody against nitrogen mustards. Briefly, human keratinocytes were exposed to SM and CEES (0–300 μM, 60 min) or HN-1, HN-2, HN-3 (120 min). After exposure, cells were scraped and DNA was isolated and normalized. 1 μg DNA was transferred to a nitrocellulose membrane using a slotblot technique. After incubation with 2F8 antibody, the DNA adducts were visualized with chromogen staining (3,3′-diaminobenzidine (DAB), SeramunGrün). Blots were photographed and signal intensity was quantified. In general, DAB was superior to SeramunGrün stain. A staining was seen from 30 nM to 300 μM of SM or CEES, respectively. However, statistically significant DNA adducts were detected after CEES and SM exposure above 30 μM which is below the vesicant threshold. No signal was observed after HN-1, HN-2, HN-3 exposure. The total hands-on time to complete the assay was about 36 h. Further studies are necessary to validate SM or CEES exposure in blister roofs of exposed patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemico-Biological Interactions - Volume 206, Issue 3, 5 December 2013, Pages 523–528
نویسندگان
, , , ,