کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5862286 | 1133775 | 2014 | 10 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A robotic BG1Luc reporter assay to detect estrogen receptor agonists
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
NICEATMRLUICCVAMCCIOECDEFMRPMIEC50EtOHNTPFBSEDC17β-estradiol - 17β استرادیولDMSO - DMSOEthanol - اتانولEstrogen - استروژنstandard deviation - انحراف معیارICI - اینجاNational Toxicology Program - برنامه سم شناسی ملیBisphenol A - بیسفنول ای، بیسفنول ADimethyl sulfoxide - دیمتیل سولفواکسیدOrganization for Economic Cooperation and Development - سازمان همکاری های اقتصادی و توسعهfetal bovine serum - سرم جنین گاوcalf serum - سرم گوسالهendocrine disrupting chemical - شیمیایی خرابکار غدد درون ریزEstrogenic activity - فعالیت استروژنیکRoswell Park Memorial Institute - مؤسسه یادبود پارک Roswellendocrine disruptor - مختل کننده غدههای درون ریزInteragency Coordinating Committee on the Validation of Alternative Methods - کمیته هماهنگی بین ادارات اعتبار سنجی روش های جایگزینVehicle control - کنترل خودروsham control - کنترل شامEstrogen receptor - گیرنده استروژن
موضوعات مرتبط
علوم زیستی و بیوفناوری
علوم محیط زیست
بهداشت، سم شناسی و جهش زایی
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
Endocrine disrupting chemicals with estrogenic activity (EA) have been associated with various adverse health effects. US agencies (ICCVAM/NICEATM) tasked to assess in vitro transcription activation assays to detect estrogenic receptor (ER) agonists for EA have recently validated a BG1Luc assay in manual format, but prefer robotic formats. We have developed a robotic BG1Luc EA assay to detect EA that demonstrated 100% concordance with ICCVAM meta-analyses and ICCVAM BG1Luc results in manual format for 27 ICCVAM test substances, i.e. no false negatives or false positives. This robotic assay also consistently assessed other, more problematic ICCVAM test substances such as clomiphene citrate, L-thyroxin, and tamoxifen. Agonist responses using this robotic BG1Luc assay were consistently inhibited by the ER antagonist ICI 182,780, confirming that agonist responses were due to binding to ERs rather than to a non-specific agonist response. This robotic assay also detected EA in complex mixtures of substances such as extracts of personal care products, plastic resins or plastic consumer products. This robotic BG1Luc assay had at least as high accuracy and greater sensitivity and repeatability when compared to its manual version or to the other ICCVAM/OECD validated assays for EA (manual BG1Luc and CERI).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Toxicology in Vitro - Volume 28, Issue 5, August 2014, Pages 916-925
Journal: Toxicology in Vitro - Volume 28, Issue 5, August 2014, Pages 916-925
نویسندگان
Matthew A. Stoner, Chun Z. Yang, George D. Bittner,