کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6064616 1201863 2014 15 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Standardized quality (SQ) house dust mite sublingual immunotherapy tablet (ALK) reduces inhaled corticosteroid use while maintaining asthma control: A randomized, double-blind, placebo-controlled trial
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی ایمونولوژی
پیش نمایش صفحه اول مقاله
Standardized quality (SQ) house dust mite sublingual immunotherapy tablet (ALK) reduces inhaled corticosteroid use while maintaining asthma control: A randomized, double-blind, placebo-controlled trial
چکیده انگلیسی

BackgroundInvestigations meeting current standards are limited for the effect of house dust mite (HDM) allergy immunotherapy in asthmatic patients.ObjectiveThis trial investigated the efficacy and safety of a standardized quality (SQ; allergen standardization method proprietary to the trial sponsor) HDM SLIT-tablet (ALK, Hørsholm, Denmark) in adults and adolescents with HDM respiratory allergic disease. This publication reports the results of the endpoints related to asthma.MethodsSix hundred four subjects 14 years or older with HDM allergic rhinitis and mild-to-moderate asthma were randomized 1:1:1:1 to double-blind daily treatment with one of 3 active doses (1, 3, or 6 SQ-HDM) or placebo. Their use of inhaled corticosteroid (ICS) was standardized and adjusted at baseline and the end of treatment to the lowest dose providing asthma control. The primary end point was a reduction in ICS dose from the individual subject's baseline dose after 1 year of treatment.ResultsThe primary analysis revealed a mean difference between 6 SQ-HDM and placebo in the reduction in daily ICS dose of 81 μg (P = .004). Relative mean and median reductions were 42% and 50% for 6 SQ-HDM and 15% and 25% for placebo, respectively. No statistically significant differences were observed for the other assessed asthma parameters, reflecting the intended controlled status of the trial subjects. The most common adverse events were local reactions in the mouth. The rate and severity of adverse events were higher for 3 and 6 SQ-HDM than for 1 SQ-HDM and placebo.ConclusionEfficacy in mild-to-moderate asthma of 6 SQ-HDM relative to placebo was demonstrated by a moderate statistically significant reduction in the ICS dose required to maintain asthma control. All active doses were well tolerated.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Allergy and Clinical Immunology - Volume 134, Issue 3, September 2014, Pages 568-575.e7
نویسندگان
, , , , , , , , ,