کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6062518 1201841 2016 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Mechanisms of allergy and clinical immunologyDeficiency of plasminogen activator inhibitor 2 in plasma of patients with hereditary angioedema with normal C1 inhibitor levels
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی ایمونولوژی
پیش نمایش صفحه اول مقاله
Mechanisms of allergy and clinical immunologyDeficiency of plasminogen activator inhibitor 2 in plasma of patients with hereditary angioedema with normal C1 inhibitor levels
چکیده انگلیسی

BackgroundHereditary angioedema with normal C1 inhibitor levels (HAE-N) is associated with a Factor XII mutation in 30% of subjects; however, the role of this mutation in the pathogenesis of angioedema is unclear.ObjectiveWe sought evidence of abnormalities in the pathways of bradykinin formation and bradykinin degradation in the plasma of patients with HAE-N both with and without the mutation.MethodsBradykinin was added to plasma, and its rate of degradation was measured by using ELISA. Plasma autoactivation was assessed by using a chromogenic assay of kallikrein formation. Plasminogen activator inhibitors (PAIs) 1 and 2 were also measured by means of ELISA.ResultsPAI-1 levels varied from 0.1 to 4.5 ng/mL (mean, 2.4 ng/mL) in 23 control subjects, from 0.0 to 2 ng/mL (mean, 0.54 ng/mL) in patients with HAE-N with a Factor XII mutation (12 samples), and from 0.0 to 3.7 ng/mL (mean, 1.03 ng/mL) in patients with HAE-N without a Factor XII mutation (11 samples). PAI-2 levels varied from 25 to 87 ng/mL (mean, 53.8 ng/mL) in control subjects and were 0 to 25 ng/mL (mean, 4.3 ng/mL) in patients with HAE-N with or without the Factor XII mutation. Autoactivation at a 1:2 dilution was abnormally high in 8 of 17 patients with HAE-N (4 in each subcategory) and could be corrected by supplemental C1 inhibitor in 4 of them. Bradykinin degradation was markedly abnormal in 1 of 23 patients with HAE-N and normal in the remaining 22 patients.ConclusionsBradykinin degradation was normal in all but 1 of 23 patients with HAE-N studied. By contrast, there was a marked abnormality in PAI-2 levels in patients with HAE-N that is not seen in patients with C1 inhibitor deficiency. PAI-1 levels varied considerably, but a statistically significant difference was not seen. A link between excessive fibrinolysis and bradykinin generation that is estrogen dependent is suggested.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Allergy and Clinical Immunology - Volume 137, Issue 6, June 2016, Pages 1822-1829.e1
نویسندگان
, , , , ,