کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7231283 | 1470954 | 2016 | 28 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
An electrochemical nanobiosensor for plasma miRNA-155, based on graphene oxide and gold nanorod, for early detection of breast cancer
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
SPGEAuNPRuO2HRPAMPGCELNATMBSWVMWCNTsSPCE3,3′,5,5′-tetramethylbenzidine - 3،3 '، 5،5'-تترامیلیل بنزیدینGnr - GNRAlkaline phosphatase - آلکالین فسفاتاز یا فسفاتاز قلیاییAmperometry - آمپرومتری Locked Nucleic Acid - اسید نوکلئیک قفل شدهScreen-printed carbon electrode - الکترود کربن روی صفحه نمایشScreen-printed gold electrodes - الکترودهای طلا چاپ شده روی صفحهGlassy carbon electrodes - الکترودهای کربن شیشه ایElectrochemical - الکتروشیمیاییRuthenium oxide - اکسید روتنیمIndium tin oxide - اکسید قلع ایندیومGraphene oxide - اکسید گرافنITO - اینbenzoquinone - بنزوئیونونmiR-155 - به miR-155EIS - تثبیت کننده الکترونیکی تصویر یا EISEarly detection - تشخیص زود هنگامBreast cancer - سرطان پستانElectrochemical impedance spectroscopy - طیف سنجی امپدانس الکتروشیمیاییMethylene blue - متیلن آبیgold nanorod - نانولوله طلاMulti-walled carbon nanotubes - نانولوله های کربنی چند دیوارهNanobiosensor - نانویوسنسورquantum dot - نقطه کوانتومیHydroquinone - هیدروکینونSquare Wave Voltammetry - ولتاژ سنج میدان موجPalladium - پالادیوم یا پالادیمHorseradish peroxidase - پراکسیداز هوررادیشCirculating miRNA - گردش خون miRNA
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
Circulating miRNAs are emerging as novel reliable biomarkers for early detection of cancer diseases. Through combining the advantages of electrochemical methods and nanomaterials with the selectivity of the oligo-hybridization-based biosensors, a novel electrochemical nanobiosensor for plasma miR-155 detection have demonstrated here, based on thiolated probe-functionalized gold nanorods (GNRs) decorated on the graphene oxide (GO) sheet on the surface of the glassy carbon electrode (GCE). The reduction signals of a novel intercalating label Oracet Blue (OB), were measured by differential pulse voltammetry (DPV) method. The transmission electron microscope (TEM) imaging, UV-vis spectrophotometry, cyclic voltammetry (CV), field emission scanning electron microscope (FE-SEM) imaging and energy dispersive spectroscopy (EDS) were proved the right synthesis of the GNRs and correct assembly of the modified electrode. The electrochemical signal had a linear relationship with the concentration of the target miRNA ranging from 2.0 fM to 8.0 pM, and the detection limit was 0.6 fM. Furthermore, the nanobiosensor showed high Specificity, and was able to discriminate sharply between complementary target miRNA, single-, three-base mismatch, and non-complementary miRNA. Alongside the outstanding sensitivity and selectivity, this nanobiosensor had great storage ability, reproducibility, and showed a decent response in the real sample analysis with plasma. In conclusion, the proposed electrochemical nanobiosensor could clinically be used in the early detection of the breast cancer, by direct detection of the plasma miR-155 in real clinical samples, without a need for sample preparation, RNA extraction and/or amplification.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 77, 15 March 2016, Pages 99-106
Journal: Biosensors and Bioelectronics - Volume 77, 15 March 2016, Pages 99-106
نویسندگان
Mostafa Azimzadeh, Mahdi Rahaie, Navid Nasirizadeh, Khadijeh Ashtari, Hossein Naderi-Manesh,